Posts Tagged ‘Energy Code’

Refrigerants

September 3, 2015

p1010584*EPA answers questions on R-22a and R-22

*Class I Ozone-depleting refrigerants

*Con Edison net metering FAQ

ASHRAE Climate Zones

December 3, 2013

0808_webex_climate_zones MeXSI Inc

2009 ECC 402.2.2

February 1, 2012

* Supply duct leaking: a discussion on testing as required by the Energy Conservation Code. 

ASHRAE 90.1 2007

June 9, 2011

* Training slide show for 90.1, with Zone 5 conditions for exterior skin cited.

Energy Maps

May 29, 2011

* Mapcruzin has several maps of US nuclear generation facilities and historic seismic activity.

* Baker Hughes has an interactive rig count for North America. It includes oil, gas, and geothermal well rig deployment for the entire industry. Rig count is up appreciably year-over-year, primarily because of oil drilling. Natural gas drilling is down.

* The US roofing association has the ASHRAE 90.1 2007 climate zone map in color. The one that ASHRAE publish in the print version of 90.1 2010 is nearly illegible.

ASHRAE 90.1-2010 8. POWER

April 9, 2011

8.4.2 Automatic Receptacle Control. At least 50% of all 125 volt 15- and 20-A receptacles…installed in the following space types:

a. Private offices

b. Open offices

c. Computer Classrooms

shall be controlled by an automatic control device that shall function on:

a. a scheduled basis using a time-of-day operated control device that turns receptacles off at specified … times– an independent program schedule shall be provided for areas of no more that 25,000 SF but not more than one floor, or

b. an occupant sensor that shall turn receptacles off within 30 minutes of … occupants leaving…, or

c. a signal from another control… that indicates the area is unoccupied.

Exceptions: Receptacles for the following shall not require an automatic control device:

a. Receptacles … designated for equipment requiring 24-hour operation.

b. Spaces where … shutoff would endanger the safety or security…

8.5 Prescriptive Path (Not Used)

8.6 Alternative Compliance Path (Not Used)

8.7 Submittals

8.7.1 Drawings … record (as-built) drawings of the actual installation shall be provided…

NYC CD Compliance with Energy Code

March 23, 2011

NOTICE OF PUBLIC HEARING
Subject:
Opportunity to comment on proposed amendment to Section 5000-01 of Title 1 of the Rules of the City of New York relating to construction document compliance with the Energy Code.
Date / Time:
March 28, 2011/ 10:00 a.m.
Location:
Department of Buildings
280 Broadway, 6th Floor Training Room
New York, NY 10007

Proposed Rule Amendment
…the Department of Buildings proposes to amend Section 5000-01 of Chapter 5000 of Title 1 of the Rules of the City of New York…

Written comments and a summary of oral comments received at the hearing will be available until April 28, 2011 at the Office of the Commissioner, Department of Buildings, 280 Broadway, 7th floor, New York, NY 10007.

please email me for PDF of proposed changes.

NYC Local Laws and building energy use

February 12, 2011

*As part of PlaNYC, the City has passed four pieces of legislation that make the energy code stricter, require installation of lighting upgrades and tenant meters in non-residential spaces, and require most buildings over 50,000 SF to undertake benchmarking audits, and implement retro-commissioning measures. The rules also deal with lighting efficiency, but the required changes do not take affect until 2025. One change which immediately impacts existing buildings: beginning in May, all NYC buildings over 50,000 SF will be required to file annual energy and water use reports with the Department of Finance. For a comprehensive PDF of the new rules, please email me.

ASHRAE

February 11, 2011

* ASHRAE 90.1 2010 is now available as print or download. I will try to follow with comments after reviewing it.

* ASHRAE are developing bulletin 201P, their smart grid standard. This is being done in partnership with NEMA. I spoke to the ASHRAE president last night, who explained ASHRAE are involved because of the impact of smart grid power and protocols on building mechanical equipment operation.

NYC ECC and COMcheck

November 3, 2010

* DoB now accepts DOE-sponsored software to verify NYC ECC compliance for design projects, available for Windows and Mac OS.

* DOE has released a new version of EnergyPlus building energy simulation software.

* Ancient Romans had some of the same issues facing us today in NYC: collapsing buildings, and devising energy efficiency measures.

Maiden Lane facade of 2 Federal Reserve Plaza, 33 Maiden Lane, 1985. Traditional floor by floor brick exterior wall construction consisting of 6″ block backup, 2″ cavity, and 3 5/8″ Belden brick, complies with NYC ECC.